Observation of the skin-depth effect on the Casimir force between metallic surfaces
Publication information:
Lisanti, Iannuzzi, and F. Capasso. 2005. “Observation of the Skin-Depth Effect on the Casimir Force Between Metallic Surfaces”. Proceedings of the National Academy of Sciences, 102, 34, Pp. 11989-92. doi:10.1073/pnas.0505614102
Abstract
We have performed measurements of the Casimir force between a metallic plate and a transparent sphere coated with metallic films of different thicknesses. We have observed that, if the thickness of the coating is less than the skin-depth of the electromagnetic modes that mostly contribute to the interaction, the force is significantly smaller than that measured with a thick bulk-like film. Our results provide direct evidence of the skin-depth effect on the Casimir force between metallic surfaces.